Control Features
        •        Four selectable control modes – Volts/Hertz, Dynamic Torque, Sensorless Vector, Closed Loop Vector
        •        Provides drive solutions for today’s demanding motor-driven machinery
Advanced Speed and Torque Control Capabilities
        •        High levels of torque boost attainable
        •        Power loss ride through
        •        Torque limit adjustable features
Advanced Tuning Features
        •        High level of detail and information regarding applied motors
        •        Motor types range from variable torque to full flux vector motors
PID Loop Control Features
        •        Process or Dancer control
        •        Loss of feedback deTECtion
        •        Sleep-wake mode
        •        High and low feedback alarms
        •        Wide variety of process set point signals to choose from
Closed Loop Speed Control
        •        100 Hz speed loop bandwidth
        •        Full-quadrature encoder feedback with marker pulse
        •        Range: 20–60,000 counts/revolution
        •        Loss of encoder signal deTECtion with alternative operation selection
        •        PI speed loop with adjustable gains and notch filtering
Extensive Input/Output Capabilities
        •        Forward and Reverse inputs plus seven assignable digital inputs
        •        Over 50 settings available; each assignable as normally open or normally closed state
        •        Three analog inputs: 0 to ±10V or 0 to 10V, 4 to 20 mA, 0 to ±10V signals
        •        Assignable frequency reference, PID set point or feedback, torque reference, torque gain, plus many choices
        •        Two analog outputs: selectable as 0 to 10V or 4 to 20 mA output, scaling, plus over a dozen configuration choices such as output frequency, current, voltage, torque, plus more
        •        Four transistor type outputs; over 50 settings available; each assignable as normally open or normally closed state
        •        Two assignable contact outputs; over 50 settings as with the transistor outputs
        •        Pulse train input
Monitoring and Diagnostics
        •        Extensive monitoring capabilities
        •        Detailed status information for all recorded faults (up to 4)
        •        Cumulative operating time displays for component maintenance
        •        Output frequency reduction to avoid overload trips and transistor junction over temperature